Automatic fire alarm system

Fire safety installations

What is AFAS?

An automatic fire alarm system (AFAS) detects a fire and raises the alarm automatically. Systems vary, but typically consist of detectors, manual call points, sounders and a control panel. If required, an AFAS can also be configured to send an alert directly to the emergency response centre and/or a security company’s monitoring centre.

Kuigi erinevad süsteemid omavad mitmeid ühiseid jooni, on iga ATS erinev – keskseadme, andurite ja muude osiste valik ning paiknemine kujunevad välja objekti põhiselt. Näiteks võib vahel olla kasulik asendada mõned suitsuandurid temperatuurianduritega ning sõltuvalt objektist võivad olla vajalikud ka vingugaasiandurid. Iga objekt vajab erinevat lahendust ja iga lahendus peab olema loodud vastavalt objekti eripäradele. Süsteem, mis vastab objekti vajadustele, tuvastab tulekahjusid paremini ning sellest tulenevalt esineb ka vähem valehäireid.

Seetõttu on oluline valida juba paigalduse planeerimisel usaldusväärne partner, kes oskab arvestada objekti vajaduste, ülesehituse ja eripäradega. Hilisem puuduste lahendamine kujuneb tihti kallimaks ja aeganõudvamaks.

Why does AFAS need to be maintained?

ATS süsteemide hooldamine on seadusest tulenevalt kohustuslik ning paigaldise korrashoiu ja toimepidavuse eest vastutab selle omanik. Seetõttu on eriti oluline valida usaldusväärne partner süsteemi hooldama. Lisaks seaduslikule kohustusele on veel mitmeid põhjuseid, miks süsteemi korrashoid on oluline. Ebakorrektne süsteem tähendab sagedaseid valehäireid ning võib ka viia tulekahju hilisema tuvastamiseni. Kui valehäired on lihtsalt tüütud, siis tulekahju hilisem tuvastamine võib suurendada ohtu inimelule ja ka tekitada suuremat kahju varale.

Süsteemide hooldamine on efektiivne viis tuvastamaks vead ja potentsiaalsed rikkepunktid varakult. Maintenance services ja hoolduspäevik on viis ATSiga kursis püsida – hooldused annavad märku osiste vananemisest ja ka võimalustest süsteemi parendamiseks. Tehnoloogia ei kesta igavesti, kuid korrektne hooldamine aitab jaotada süsteemi ülevalpidamisega seotud kulud pikemale perioodile ning risk, et kogu süsteem tuleb korraga asendada, on selle arvelt oluliselt vähendatud.

What is AFAS maintenance?

An AFAS is serviced quarterly, with an additional annual service. Quarterly maintenance monitors the system and identifies faults as they arise. The annual service provides a complete overview. The main difference is scope: quarterly maintenance samples components from each equipment group, while annual maintenance checks every component in every group. All maintenance is carried out in accordance with the manufacturer’s instructions.

Kvartaalse hoolduse käigus teostatakse järgmiseid töid

  • all entries made in the maintenance log are checked and acted upon;
  • the capacity of the reserve power batteries is checked;
  • the alarm, fault and auxiliary functions of the central unit are checked;
  • the devices of the automatic fire alarm system and possible signs of moisture in the central unit are visually checked;
  • all circuit checks and tests specified by the installer, supplier or manufacturer are carried out;
  • the integrity of the system’s operation is assessed and the owner is informed about the layout of the inventory and the disruptions in the system’s operation due to the way the building is used;
  • the activation of at least one sensor or fire alarm button from each circuit is checked to test the ability of the central unit to receive signals.

Quarterly maintenance is often followed by recommendations to tidy up the system or eliminate deficiencies, which can be sensor replacements, battery replacements, or changing the locations of system parts.

Aastase hoolduse käigus teostatakse järgmiseid töid

  • the operation of each sensor, manual call point and alarm device is checked according to the manufacturer’s recommendations. Components are cleaned and serviced as needed;
  • all cable connections and equipment condition are visually checked;
  • the condition of the batteries is checked;
  • the operation of all devices and applications controlled by the central unit connected to the system is checked.

Since all system parts are checked during the annual maintenance, technicians must have access to all rooms where the system parts are located.

Frequently asked questions

How often should AFAS be serviced?

AFAS is serviced quarterly, or three times a year, plus annual maintenance.

Who is responsible for maintaining the AFAS?

The owner of the installation is responsible for system maintenance. Therefore, it is especially important to choose a reliable partner.

Could I perform AFAS maintenance myself?

In general, you can’t – the person performing the maintenance work must have the appropriate qualifications. If you do not have them, you need a person with the appropriate qualifications to carry out the maintenance.

What happens if the AFAS is not maintained?

Ensuring that the system is maintained is the responsibility of the installation owner, but neglecting to do so increases other risks in addition to non-compliance with the law. An unmaintained AFAS may display false alarms more often, and in the event of a fire, the system may fail to detect a crisis. Regular maintenance helps to identify and anticipate errors and specific requirements within the system at an early stage.

What to do if the AFAS gives an error message?

Error messages should be taken seriously. If the AFAS shows an error message, it must be noted in the maintenance log and the system maintainer must be informed about it immediately.

How long is the lifetime of the sensor?

The lifetime of the sensor is generally up to 10 years at most.